CLEANING & PACKAGING
HAM-LET H400-HP valves are treated with HAM-LET Passivation, Cleaning and Packaging (Procedure 8075). HAM-LET H400-HP Valves with face-seal end connections are treated with HAM-LET Oxygen Cleaning and Packaging (Procedure 8055). Oxygen Cleaning and Packaging for other end connections are available as an option.
|
TESTING
The H400-HP valve designs have been tested for Proof and Burst. Every H400-HP valve is factory tested for proper assembly, by leakage detection at 1000 psig (68 bar) for 10 seconds. Every H400-HP valve is factory tested for functionality at the relevant cracking pressure, 5 cycles each.
|