CLEANING & PACKAGING
HAM-LET H400-A valves are treated with HAM-LET Passivation, Cleaning and Packaging (Procedure 8075). HAM-LET H400-A valves with face-seal end connections are treated with Ham-Let Oxygen Cleaning and Packaging (Procedure 8055). Oxygen cleaning and packaging for other end connections are available as an option.
|
TESTING
The H400-A valve designs have been tested for Proof and Burst. Every H400-A valve is factory tested for proper assembly, by leak detection at 1000 psig (68 bar) for 10 seconds. Every H400-A valve is factory tested for functionality at the relevant cracking pressure, 5 cycles each.
|